Polyurethane based heavy duty, waterproof and UV resistant car park decking system
Vetodeck UD is a multi-layer deck protection system comprising a primer, waterproof membrane and protective top coat. All components are applied in the liquid phase and react chemically to form a tough, flexible, protective surface. Vetodeck AD system is designed to provide an added level of protection to, new and existing, heavily trafficked areas.
Vetodeck Components are supplied in:
Vetoprime EP490 is supplied in 4 & 15 liters Kit, Coverage: 7 - 10 m2 /Liter
Vetotop UC 363 is supplied in 4 & 15 liters Kit, Coverage: 1.25 m2 /Liter
Vetotop UC370 is supplied in 4 & 15 liters Kit, Coverage: 6 m2 /Liter
Vetotop UC373 is supplied in 1 & 4 liters Kit, Coverage: 70LM x 10cm / Liter
Original sealed bags of Vetodeck UD components has a shelf life of 12 months provided it is stored clear of ground in a dry and shaded place below 35ºC.
Priming
Apply Vetoprime EP490 to the prepared surface at a wet film thickness of 100 microns.
Application
Membrane:
Apply Vetotop UC363 to Vetoprime EP490 surface at a wet film thickness of 750 - 900 microns. For best results Vetotop UC363 should be applied with a notched trowel or squeegee. If Vetotop UC363 is still wet, seed with Saveto Vetograin - Grain No. 2 at a rate of 0.5kg/m2 and allow to cure for 16 hours at 25ºC.
Top Coat:
Apply Vetotop UC370 top coat to the membrane coat at a wet film thickness of 300 microns. When application is complete the system should be permitted to cure for 72 hours @ 35°C or 7 days @ 25°C prior to being trafficked.
Line Marking:
Apply Vetotop UC373 as a line marking paint. Vetotop UC373 is available in a range of traffice RAL colors.
Cleaning
All tools and equipment should be cleaned immediately after use with Vetonit Solvent.
Existing surfaces should be sound, clean, free from loose material, grease, laitance, dirt curing compound, etc.
Laitance and weak surface layer shall be removed using mechanical methods such as grinding or blasting in order to provide a sound well profiled surface. All necessary repairs should be made prior to application by using the same material. New concrete floors shall be at least 5 days old and visibly dry with no standing water on top.
New concrete surfaces should have reached 80% of their intended physical properties - generally only achieved after a minimum curing period of 28 days. Existing concrete sur-
faces must be prepared to provide a clean, sound substrate
Vetodeck UD Components should not come into contact with skin and eyes or be swallowed. Avoid inhalation of vapour and spray. Use only in well ventilated areas. In case of insufficient ventilation wear suitable respiratory protection. Wear suitable protective clothing, gloves and eye/face protection. Barrier creams provide additional skin protection.
Should accidental skin contact occur, remove immediately with a suitable skin cleanser followed by washing with soap and water.In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.If swallowed, seek medical attention immediately - do not induce vomiting.
Refer to product MSDS for further information.
Saveto endeavors to ensure that any advice, recommendations, information it may give, is accurate and correct. It cannot accept any liability either directly or indirectly arising from the use of its products, because it has no direct or continuous control over where or how its products are applied, whether or not in accordance with any advice, specification, recommendation or information given by us. Saveto has the right to change any of the specifications mentioned in the Technical data sheets upon its discretion without prior notification.
Hard copies of TDSs are printed once or twice a year, while our technical data sheets are continuously being updated as per R&D improvements and new 3rd party testing; kindly refer to our website for the latest updated TDSs.
Hard-wearing silica aggregates to be used in conjunction of Saveto anti-slip flooring system
Premixed 2 to 10 mm thick cementitious self leveling underlayment
Premixed 10 to 30 mm thick cementitious screed.
Premixed 30 to 100 mm thick cementitious screed.
Solvent based high performance, self priming, thin epoxy topping
Elastomeric, pigmented acrylic, anti-chloride ion and carbonation protective and decorative coating for concrete and masonry