Single component penetrating waterproofing system for concrete
VETOPROOF CM741 provides a total and permanent waterproofing solution to water leakage, ingress, or seepage in concrete structures or any cementitious substrates due to its unique, surface-applied penetrative capillary water proofing system. VETOPROOF CM741 works through internal crystallization that seals the pores and hairline cracks in the concrete, thus blocking effectively further water passage. The active chemical that made up VETOPROOF CM741 catalyzes to reactivate the crystallization process every time water penetrates the structure through newly formed capillaries, therefore, ensuring permanent water tightness.
Vetoproof CM741 is supplied in 25Kg Bags.
Yield: 1.6 kg/m²/1mm thickness
Stated consumption data are for general guidance. Actual consumption depends on the nature of substrate, method of application, and wastage.
The original sealed bag of Vetoproof CM741 has a shelf life of 12 months, provided it is stored clear of ground in a dry and shaded place below 35ºC.
Mixing
If the use of masonry brush is the application method, mix 7-7.5 liters of water with 25kg of Vetoproof CM741, while when using a power-spray gun, prepare a mixture of 8 – 8.5 liters of water with 25kg of the product.
Mix only as much product as necessary and ensure to stir the mixture regularly. If the mixture starts to set, it is not advisable to add more water; instead, re-stir the prepared mixture to reinstate its workability.
Application
Apply Vetoproof CM741 into two coats with the use of a masonry brush or power-spray gun. Make sure to apply the second coat while the first coat is still “green”.
Keep all areas where Vetoproof CM741 is applied damp, protected against direct exposure from sunlight, wind, and frost by covering the area with polythene sheeting, damp hessian cloth, etc., for a period of 5-7 days.
Ensure that the period between applying the first and second layer is between 3 – 4 hours at a temperature of 20°C.
Cleaning
Clean all tools employed to apply Vetoproof CM741 with water before it hardens; otherwise, mechanical means are needed.
All surfaces where Vetoproof CM741 has to be applied must be clean and have an open capillary system. Eliminate laitance, dirt, grease, and other loose materials utilizing high-pressure water jetting or wet sandblasting. Defective concretes such as cracks and honeycombs, etc., have to be chased out and repaired before the application. Also, make sure that all surfaces must be damp but not totally wet before progressing the work.
Do not apply Vetoproof CM741 on temperatures below 5°C.
Vetoproof CM741 could not be used as an additive to concrete or plasters.
Vetoproof CM741 is not suitable for use as curing compounds.
Vetoproof CM741 contains cement powders that release alkalies that can be harmful to the skin when mixed or become damp. During use, avoid inhalation of dust and contact with skin and eyes. Wear suitable protective clothing, gloves, eye protection, and respiratory protective equipment. The use of barrier creams provides additional skin protection. In case of skin contact, rinse with plenty of clean water, then cleanse with soap and water. In case of contact with the eye, rinse immediately with plenty of clean water and seek medical advice. If swallowed, seek medical attention immediately – do not induce vomiting.
Vetoproof CR747 is non-flammable.
Saveto endeavors to ensure that any advice, recommendations, information it may give is accurate and correct. It cannot accept any liability either directly or indirectly arising from the use of its products because it has no direct or continuous control over where or how its products are applied, whether or not following any advice, specification, recommendation, or information given by us. Saveto has the right to change any of the technical datasheets' specifications upon its discretion without prior notification.
Hard copies of TDSs are printed once or twice a year. Our technical data sheets are continuously updated as per R&D improvements and new 3rd party testing; kindly refer to our website for the latest updated TDSs.
Single component flexible hybrid roof water proofing membrane
Single component acrylic waterproofing membrane
Single component elastomeric crack-bridging cementitious waterproof membrane
Single component flexible pure acrylic waterproofing membrane
Polymer modified water resistant cementitious top coat
Plasticized expanding grout admixture