تجاوز إلى المحتوى الرئيسي
Submitted by webmaster on 5 June 2024

ڤيتوثيرم بانيل

لوح عازل حراري مغطى بالبوليسترين الموسع.

Saveto Vetotherm Panel is a thermal insulating external wall finish system composed of prefabricated expanded polystyrene base profiles, covered with a white color synthetic thermosetting acrylic resin shell, incrusted by highpressure mechanical laying (standard) or spraying. Vetotherm Panel is delivered to the site as a pre-coated panels ready to install. Vetotherm Panel facade system offers a complete prefabricated range of profiles for thermal insulating, decorating, and finishing facades. The system is recommended for new constructions and renovations, where facade aesthetics with high-quality thermal insulation.

الاستخدامات

  • Prefabricated expanded coated polystyrene is used as decorative thermal insulating panels for residential and industrial concrete buildings. 
  • Saves energy consumption related to heating and cooling.

المزايا

  • Prefabricated and precoated panel ready to install on-site. 
  • Fast installation saves labor cost & time. 
  • Flexible and durable with a very high weathering fluctuating resistance. It provides better protection against rain and summer rays and high temperatures. 
  • Available in different required densities and thicknesses to achieve the desired thermal values. 
  • Low water absorption and penetration due to its special composition. 
  • Elastic and does not require fiber mesh installation. 
  • High resistance to mechanical stress due to flexibility 
  • Topcoat Paint is applied directly on surfaces. 
  • Its' white-colored coating facilitates the application of bright and vibrant colors. 
  • Supplied in different shapes and decorative effects that provide a new appearance for the renovated and new Facades. 
  • Easy to maintain by spot repairing.

تعليمات الاستخدام

The substrate should be sound, clean, free from loose material, grease, laitance, dirt curing compound, etc.

 Remove all crumbles from the surface, and fill the holes to a straight flat surface. The uneven surface with a deviation of more than 1-2cm should be evened to a flat surface.

Install a plinth profile with a drip edge profile to prepare the facade’s initial arrangement. Choose the profile according to the thickness of the thermal insulating material. Level the profile by using the leveling methods and secure it with screw anchors. 

The profiles will horizontally level the Vetotherm Panel and the Thermal Insulation System installation.

- Non-faced concrete. 

- Concrete faced with a coating, with stoneware, or with mosaic (Tesserae). 

- Coated masonry. 

- Wood facade (consult the installation model with the technical Department). 

- Ceramic/Stone tile suspended facade. 

- Metal/Concrete/Wood struts/columns.

Use Saveto Vetotherm Flex as an adhesive applied to the bottom sides of the Vetotherm Panel. 

Apply the adhesive in a continuous framework along the insulation panel’s edge and form three or four balls in the middle of the panel. Stick the panels to the wall. Make sure that the adjacent vertical joints are interchanged like brickwork. Do not leave joints or spaces between the boards, and if you get larger gaps, fill them with insulation material or construction foam, but do not fill the gaps with adhesive. 

At the external edges, the panels should be interchanged. Around the corners of windows and doors, you must put the Vetotherm Panel as a whole. After the complete drying of the adhesive (min. 48 hours), cut the extended parts of the panels on site along the contour of the window or door - the so-called ‘gun.’

Before anchoring the boards, Leave Vetotherm Panels undisturbed for at least 48 hours to allow the adhesive Vetotherm Flex to dry completely.

Refer to Dowel Usage & Anchoring Table to mount the dowels, which depends on the building’s height, the region, and the wind’s strength. 

If the Vetotherm Panel thickness exceeds 8cm, you need to make a hole of 2cm depth with a cutter and then drill an opening for the screw anchor. 

When mounting the dowels, fill the hole with a polystyrene cap. After completing the anchoring, cover the dowels’ heads with Saveto Vetotherm Flex to flush with the boards’ level. 

For further information, please refer to the Saveto Vetotherm Panel Installation manual.

- For any building, the quantity of dowels is calculated according to elevation. 

- “Area” fixing pattern is chosen according to “Anchoring Patterns.” 

- “Rim zone” fixing pattern is chosen according to “Additional anchoring at Shoreline. 

- Shoreline: Constant depending on the chosen pattern. 

- The Rim Zone fixings are calculated as table value indicated accordingly for 1m2 on each of the 2 sides of the building’s external corners (or internal if applicable to case) and multiplied by building height at each external corner and summed up.

تحميل

Please login to download

استكشف المزيد من المنتجات

كوول مورتر

مونة بناء أسمنتي عازل للحرارة.

ڤيتوثيرم بلاستر

لياسة أسمنتية متطورة عازلة للحرارة .

ڤيتوثيرم فليكس

لاصق أسمنتي وطبقة أساس لنظام العزل الخارجي EIFS/ETICS.